Abstract

Objective: Traumatic injuries of os scaphoideum are serious, and might lead to two main grades of consequences (i.e. osteoarthrosis or avascular necrosis), if a fracture remains undiagnosed. Bone bruise may be the only pathological sign of pain which can last for week or month. Articles describe the importance of early MRI and hereby predict bone bruise with the help of fat suppression sequence; however, only a limited selection articles compares various fat suppression techniques. The purpose of this prospective study was to compare the short tau inversion recovery (STIR) and T2 fat saturation (FAT SAT) sequences, sectional directed along the scaphoid bone axis. In relation to background fat intensity suppression, this study sought the sequence that best evaluated posttraumatic bone marrow edema (bone bruise) on scaphoid injury musculoskeletal magnetic resonance imaging (MRI, 1.5 T extremity scanner).

Materials and methods: Two hundred and fifty-one patients with relevant trauma and positive clinical test for scaphoid bone fractures, exceeding no more than 14 days, underwent MRI examinations. A fast STIR and T2 FAT SAT fast spin echo sequence (FSE) were obtained using a comparable parameter setting (scan time ca. 3 minutes). Three experienced readers (one radiographer and two radiologists) carried out the evaluation blinded to each other’s, based on a quantitative assessment of size (area) and image quality (image contrast, IC and contrast-to-noise ratio, CNR). The study period lasted March 2014-April 2015. Sixty patients met the inclusion criteria and were enrolled. This prospective study was ethically approved by the institutional review board.

Results: There were no significant difference between the bone bruise areas (P=0.45, P=0.44 and P=0.83) or CNR (P=0.31, P=0.38 and P=0.17). However, image contrast showed significant difference in favour of T2 FAT SAT in all three readers’ reports (P<0.05, P<0.05 and P<0.05).

Conclusions: The two sequences appear almost identical. An interchangeable usage of the two sequences was found being acceptable for the diagnosis if the protocol is composed appropriately (1.5T). However, the T2 FAT SAT provided a higher image contrast by specific settings (e.g. short TI = 125 ms) compared to STIR.

Author Biographies

Louise Meincke

Metropolian University College. Faculty of Health and Technology, Copenhagen, Denmark

Ivanov Radev Dimitar

Gentofte Hospital. Department of Diagnostic Radiology, Kildegårdsvej 28, 2900 Hellerup, Denmark

Rie Eriksen

Copenhagen University Hospital Rikshospitalet. Department of Diagnostic Radiology, Blegdamsvej 9, Denmark

Carsten Ammitzbøl Lauridsen

Metropolian University College. Faculty of Health and Technology, Copenhagen, Denmark

References

1. Deangelis JP, Spindler KP. Traumatic Bone Bruises in the Athlete’s Knee. Sports Health. 2010 Sep;2(5):398–402. https://doi.org/10.1177/1941738110377745

2. Geijer M. Diagnosis of scaphoid fracture: optimal imaging techniques. Reports in Medical Imaging. 2013;57–69. https://doi.org/10.2147/RMI.S48951

3. Eustace S, Keogh C, Blake M, Ward RJ, Oder PD, Dimasi M. MR imaging of bone oedema: mechanisms and interpretation. Clinical Radiology. 2001 Jan;56(1):4–12. https://doi.org/10.1053/crad.2000.0585

4. Del Grande F, Santini F, Herzka DA, Aro MR, Dean CW, Gold GE, et al. Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System. Radiographics. 2014;34(1):1–12. https://doi.org/10.1148/rg.341135130

5. Murthy NS. The role of magnetic resonance imaging in scaphoid fractures. Journal of Hand Surgery. 2013 Oct;38(10):2047–54. https://dx.doi.org/10.1016/j.jhsa.2013.03.055

6. Resnick DL, Kang HS, Prefferklieber ML. Internal Derangements of Joints, Vol 1. 2nd Eds. Saunders. 2007

7. Thavarajah D, Syed T, Shah Y, Wetherill M. Does scaphoid bone bruising lead to occult fracture? A prospective study of 50 patients. Injury. 2011;42(11):1303–6. https://doi.org/10.1016/j.injury.2011.02.020

8. Mccullough MP, Smith FW, Cooper JG. Early MRI in the management of the clinical scaphoid fracture. European Journal of Emergency Medicine. 2011 18(3) 133-6.
https://doi.org./10.1097/MEJ.0b013e32833edb59

9. Taljanovic MS, Karantanas A, Griffith JS, Desilva GL, Rieke JD, Sheppard JE. Imaging and Treatment of Scaphoid Fractures and Their Complications. Seminars in Musculoskeletal Radiology. 2012;16(2):159–74. https://doi.org/10.1055/s-0032-1311767

10. Rhemrev SJ, Ootes D, Beeres F, Meylaerts S, Schipper IB. Current methods of diagnosis and treatment of scaphoid fractures. International Journal of Emergency Medicine. 2011;4(4). https://doi.org/10.1186/1865-1380-4-4

11. Mallee W, Doornberg JN, Ring D, van Dijk CN, Maas M GJ. Comparison of CT and MRI for diagnosis of suspected scaphoid fractures. Journal of Bone & Joint Surgery. 2011;93(1):20–8. https://doi.org/10.2147/RMI.S48951

12. Sendher R, Ladd AL. The Scaphoid. Orthopedic Clinics of North America. 2013;44(1):107–20. https://doi.org/10.1016/j.ocl.2012.09.003

13. Bergh TH, Lindau T, Soldal LA, Bernardshaw SV, Behzadi M, Steen K BC. Clinical scaphoid score (CSS) to identify scaphoid fracture with MRI in patients with normal x-ray after a wrist trauma. Emergency Medicine Journal. 2014;31(8):659–64. https://doi.org/10.1136/emermed-2012-202219

14. Shetty S, Sidharthan S, Jacob J, Ramesh B. “Clinical scaphoid fracture”: Is it time to abolish this phrase? Annals of The Royal College of Surgeons of England. 2011;93(2):146–8. https://doi.org/10.1308/147870811X560886

15. Cameron I. Techniques of Fat Suppression. MR Phys Ottawa Hosp 501 Smyth Rd, Ottawa, ON, Canada. 2009;7 http://cds.ismrm.org/protected/09MProceedings/files/Tues C36_01 Cameron.pdf

16. Kijowski1 R , Farber JM, Medina J, Morrison W, Jyng J, Buckwalder K. Comparison of Fat-Suppressed T2-Weighted Fast Spin-Echo Sequence and Modified STIR Sequence in the Evaluation of the Rotator Cuff Tendon. American Journal of Roentgenology. 2005;185(2):8. https://doi.org/10.2214/ajr.185.2.01850371

17. Dodd JD. Evidence-Based Practice in Radiology: Steps 3 and 4--Appraise and Apply Diagnostic Radiology Literature. Radiological Society of North America. 2007;242(2):342–54. https://doi.org/10.1148/radiol.2422051679

18. Razavi SA, Sadigh G, Kelly AM CP. Comparative effectiveness of imaging modalities for the diagnosis of upper and lower urinary tract malignancy: a critically appraised topic. Academic Radiology. 2012;19(9):1134–40. https://doi.org/10.1016/j.acra.2012.05.004

19. El-Maraghi RH KA. CT colonography versus optical colonoscopy for screening asymptomatic patients for colorectal cancer a patient, intervention, comparison, outcome (PICO) analysis. Academic Radiology. 2009;16(5):564–71. https://doi.org/10.1016/j.acra.2009.01.008

20. GE Healthcare, Milwaukee. ONI Optima 1.5T MR430s Extremity. Magnetic Resonance Imaging. [Cited 2017 April 26] Available from: http://www3.gehealthcare.com/en/support/site_planning

21. Tomura N, Saginoya T, Kokubun M, Tsuchiya M, Yamamoto T. T2-weighted IDEAL fast spin echo imaging of the brachial plexus: comparison with STIR. Acta Radiologica. 2015;0(0):1–6. https://doi.org/10.1177/0284185114552292

22. Rosner B. Fundamentals of biostatistics Belmont, CA:Thomson-Brooks/Cole. 2006.


23. McRobbie DW, Moore EA, Graves MJ, Prince MR. MRI from Picture to Proton. New York: Cambridge University Press; 2003. 359 p.